Xiamen Liuxian Industrial Co., Ltd.

Category Tag

Fluke 289C True-RMS Data Logging Multimeter

MOQ: 1 PCS
Warranty: 1 year
Delivery time: 3-5 days
Shipping method: FedEx/DHL/UPS/TNT
Payment method: TT/Western Union

  • Share results with your team using ShareLive™ video call (requires ir3000 FC wireless connector [sold separately] and no-cost Fluke Connect mobile app).
  • TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
  • Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
  • Selectable AC filter (smoothing mode) helps display a steadier reading when the input signal is changing rapidly or noisy.
  • Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
  • LoZ Volts. Low impedance voltage function for eliminating ghost voltages. Also recommended when testing for absence or presence of live power.
  • Adjustable recording and auto hold thresholds, specify a percentage change in the readings that begins a new event.
  • Large 50,000 count, 1/4 VGA dot matrix display with white backlight.
  • Measure up to 10 A (20 A for 30 seconds).
  • 100 mF capacitance range.

Description

Data Category Specific Parameters
Product Model Fluke 289C
Brand Fluke
Product Type True-RMS Industrial Logging Multimeter真有效值工业记录万用表
Display 50,000-count 1/4 VGA dot matrix; white backlight; TrendCapture graphical display
DC Voltage Measurement Range: 50.000 mV – 1000.0 V; Resolution: 1 µV (DC mV); Basic Accuracy: ±0.025%
AC Voltage Measurement Range: 50.000 mV – 1000.0 V; True-RMS; Bandwidth: 100 kHz; Basic Accuracy: ±0.4%
DC Current Measurement Range: 500.00 µA – 10.000 A; Basic Accuracy: ±0.15%
AC Current Measurement Range: 500.00 µA – 10.000 A (20 A for 30s); True-RMS; Basic Accuracy: ±0.7%
Resistance Measurement Range: 50.000 Ω – 500.0 MΩ; 50 Ω range with 1 mΩ resolution; Basic Accuracy: ±0.05%
Capacitance Measurement Range: 1.000 nF – 100 mF; Basic Accuracy: ±1.0%
Frequency Measurement Range: 99.999 Hz – 999.99 kHz; Basic Accuracy: ±0.005%
Key Features TrendCapture (zoom up to 14x); low-pass filter; LoZ volts; ac smoothing mode; peak capture (250 µs); on-board help
Logging Capacity Stores up to 15,000 events; multiple logging sessions; time-stamped data
Dimensions (H×W×D) 22.2 cm × 10.2 cm × 6 cm (8.75 in × 4.03 in × 2.38 in)
Net Weight 870.9 g (28 oz)
Power Supply 6×AA alkaline batteries; 100-hour min runtime (200 hours logging mode)
Operating Temperature Range -20 °C to 55 °C
Storage Temperature Range -40 °C to 60 °C
Relative Humidity 0%-90% (0°C-37°C); 0%-65% (37°C-45°C); 0%-45% (45°C-55°C) (non-condensing)
Communication Optically isolated port; USB cable/software optional (for PC data transfer)
Warranty Limited lifetime warranty

 

Contact Us